Saving The Day With Superior HVAC Services For Wendell NC
Welcome to Heroes Heating & Cooling, your one-stop-shop for all HVAC needs in Wendell NC! Whether temperatures are soaring or plummeting, fear not – our team of HVAC superheroes is here to save the day. We offer a range of services to keep your home comfy and cozy, delivered with unparalleled professionalism and superhuman expertise! First, our air conditioning repair, installation and maintenance services are second to none! No matter how tricky a problem you’ve got, our super-powered technicians can handle it. But wait, there’s more! When winter’s chill descends upon us, our heating repair, installation and maintenance services come to the rescue! Our heating mastery will keep you snug and warm even through the iciest months. Plus, let’s not forget HVAC’s sidekick – indoor air quality! Our IAQ services do battle against all the dust, allergens and indoor pollutants that threaten your home. But what truly sets us apart is our team. Our superheroes are expert, friendly technicians with a passion for their craft and a commitment to swift, excellent service. So Wendell citizens, never fear HVAC troubles again! Trust Heroes Heating & Cooling to swoop in and save the day!
So if you’re in search of the ultimate HVAC heroes to rescue you from the clutches of discomfort, you’ve found them – but don’t just take our word for it. Hear it straight from your neighbors in Wendell NC. Our review pages are treasures troves of tales of satisfied customers regaling you with epic encounters with our top-notch service. Discover how we defeated faulty ACs, conquered malfunctioning furnaces and triumphed over indoor air quality villains! Then, when you’re ready to unleash the power of unbeatable comfort, send us a message online or give us a call at 919-632-0402 – we’ll be on the way!
Recent Jobs and Reviews in Wendell, NC
Our Local Reviews by City
- Apex, NC (2)
- Cary, NC (3)
- Chapel Hill, NC (2)
- Clayton, NC (2)
- Creedmoor, NC (4)
- Durham, NC (8)
- Efland, NC (1)
- Franklinton, NC (4)
- Fuquay-Varina, NC (2)
- Garner, NC (4)
- Hillsborough, NC (2)
- Knightdale, NC (2)
- Louisburg, NC (1)
- Morrisville, NC (1)
- Pittsboro, NC (3)
- Raleigh, NC (23)
- Smithfield, NC (2)
- Wake Forest, NC (2)
- Wendell, NC (1)
- Youngsville, NC (1)
Job Locations and Reviews
Preformed full system tune up. Checked duct system for growth and bacteria. Checked blower amps 2.57. Cleared Drain line. Checked compressor amps 6.5. Checked outdoor fan amps .45. Checked r410a pressures 225/135
Removed old indoor coil. Installed new indoor coil for rheem split system. System is cooling
Found front room system low on charge. Customer has leak in coil. Found back room system compressor bad. Also found bad heater kit and dual start assembly. Comfort advisor will send customer replacement option for back room. Will order coil and return to install for front room
Found wires in the wrong place. Reveresed wire compressor is now working
Found upstairs compressor not working. Customer has a bad compressor under warranty. Will order compressor under warranty and return to install
Found upstairs system operating normal. Told customer room is over garage.
Performed heating tune up. System is 2020 Coleman heat pump which services the whole home. Tested all heating components and heating operation. Also tested defrost controls. System is operating at manufacturer’s specifications at this time. Recommended installing air purification system to provide hospital quality in the home.
Here a two heat pump fall maintenance performed, and the older system has a pitted contactor that is recommended for replacement, and due to the age of the system excessive dust found in the return grille. A P-Mac filter is recommended to filter out finer particulates/ dust from the supply air. All amp draws are within tolerance for the main floor system, and are as follows idf 1.19 heat strip bank1 19.49 bank2 18.70 outdoor fan.69 compressor 6.16 dual start assembly giving what it’s rated for at 45/5 uf upstairs indoor fan amps .93 heat strip 18.01 compressor 5.01 outdoor fan.81 dual start assembly found at 39.5/5 within manufacturing specifications. The indoor coil for the upstairs system is severely rusted, and near future may display a leak in the system resulting in replacement of the system, or coil.
Arrived to perform 2 system heating maintenance. Systems are 2022 Coleman heat pumps which service the first and second floors independently. Performed inspection/test of all heating components along with heating operation. Systems are operating at manufacturer’s specifications at this time. Recommended replacement of vapor barrier under the home due to many spots being bare which will allow the subfloor to absorb moisture. Thank you for choosing Heroes Heating And Cooling!
Found 2014 Goodman heat pump outdoor unit not running upon arrival. Upon further inspection found bad dual start assembly. Told customer every time system starts the compressor and outdoor fan are both getting damaged. Also found contactor contacts pitted. Found dirty duct system. Found outdoor condenser coils dirty. Gave customer options to make repairs. Customer only wants to replace dual start assembly. Replaced dual start assembly. System started up. Found system low on charge. Told customer about leak. Customer wants to leave it the way it is for now
During service call, tech found malfunctioning blower motor and unit is low on refrigerant. This may indicate a leak. Due to unit’s condition, tech recommends unit upgrade.
Customer cancelled
Found system blower motor not cutting on sometimes. Customer has a bad single start assembly. Told customer every time system starts the blower motor is getting damaged. Also found system low on r22 charge. Customer has a leak in coil. Flounder electronic circuit system going bad. Found contactor assembly pitted. Found duct system dirty. Gave customer options to make repairs. Customer wants to talk to comfort advisor about replacement